Osvanta

Configurations and sessions

Save your work as a configuration, and reopen the last session at the next start.

Save a configuration

File ▸ Save configuration (Ctrl+S) saves the session to a .json file. File ▸ Open configuration brings it all back.

A configuration holds:

  • the paths of the measurement and the databases, and which database belongs to which channel;
  • the calculated signals;
  • the plotted signals, with their order, groups, colours, line styles and visibility;
  • every plot tab, the axes, the cursors and the markers;
  • the display settings.

A configuration holds paths, not the data itself. To open it on another computer, the measurement and the databases must be reachable there too.

File ▸ Open configuration is greyed out while a measurement is decoding.

Closing with unsaved changes

Closing with changes you have not saved asks whether to save them.

The last session

Whatever you answer when closing, the application keeps the session, and the next start offers to reopen it. This also works after a crash: the last session is refreshed once a minute while you work.

Where these files are

File Where
Configurations you save Wherever you save them
The last session and your preferences %LOCALAPPDATA%\Osvanta\BusLogAnalyzer

These files hold the names of your measurement, databases and signals. Treat them as being as confidential as the measurement itself. See Security and data handling for the full list.

Older versions

A configuration keeps every plot tab. An older version of the application that has no tabs opens the first tab.