Read values with the two cursors, zoom into a time range, and get statistics from the signal table.
Cursors
| Key or mouse | Action |
|---|---|
| Click on the plot | Place Cursor 1 there, switching it on if it is off |
Shift+click on the plot |
Place Cursor 2 there, switching it on if it is off |
R |
Switch both cursors on or off together |
| Drag a cursor | Move it |
The line under the plot shows both cursor times and the time between them. The signal table shows each signal’s value at each cursor.
A cursor that is switched on always appears inside the visible window. Cursors are black on a light plot background and white on a dark one.
Zoom and fit
| Key or mouse | Action |
|---|---|
F |
Fit to Window: the whole recording, in time and height |
V |
Fit Vertical: the height only, keeping the time range |
Z |
Switch Rectangle Zoom on or off |
| Drag on the plot, in Rectangle Zoom | Zoom into the box |
Shift+drag, in Rectangle Zoom |
Zoom out around the box; a smaller box zooms out further |
| Double-click on the plot, in Rectangle Zoom | See the whole recording again |
Esc |
Leave Rectangle Zoom |
Fit to Window and Fit Vertical work in every plot mode.
Signal table columns
Right-click the signal table’s header to show or hide a column.
| Column | What it shows |
|---|---|
| Cursor values | The signal’s value at Cursor 1 and at Cursor 2 |
| Hex | Cursor 1’s value as the raw value on the bus, in hexadecimal |
| Δ C2−C1 | Cursor 2’s value minus Cursor 1’s |
| Unit | The unit from the database |
| Min, Max, Mean | The smallest, largest and average value |
| Std dev, RMS | Standard deviation and root mean square |
| Samples | How many samples were counted |
Which range the statistics cover
- With both cursors on, the statistics are between the cursors.
- Otherwise, they cover the visible range.
So to measure one part of a recording, place Cursor 1 at its start and Cursor 2 at its end.
How Hex is worked out
Hex turns the value back into what the bus carried: (value − offset) / factor from the database, padded to the signal’s length.
- An 11-bit signal reads
0x7FFat its maximum. - An 8-bit signed −1 reads
0xFF. - A float signal shows its IEEE 754 bits.
- A signal that no database defines, such as a calculated signal or an MF4 channel the file decoded itself, shows its value in hex when it is a whole number, and nothing otherwise.